logo


Articles & News
General Information
Permeator Presentation
Domestic Activities
Download Brochure
Company History
Contact Us
 
ARID Technologies, Inc
323 S. Hale Street
Wheaton, IL 60187
tel:(630) 681-8500
fax:(630) 681-8505

Project No. 148
Test Report for the ARID Technologies Vapor Recovery Unit
installed in LANTANA, FL


Prepared for: Arid Technologies, Inc.
Prepared By: Matus Technical Services, Inc.

1.0 Introduction

Matus Technical Services, Inc. (MTS) conducted an emission test program at a retail gasoline loading station located in Lantana, FL for the purpose of demonstrating capture efficiency of the Arid Technologies, Inc. vapor control unit and for the purpose of comparing vent stack emissions when PERMEATOR® is "OFF" versus "ON".

The testing period was continuous and lasted approximately 72 hours in length. Sampling was conducted at the outlet vent to the underground storage tanks when the PERMEATOR® was "OFF" and at three locations from the PERMEATOR® vapor recovery unit which is operated to control hydrocarbon (VOC) emissions during gasoline dispensing operations.

The emission rates are reported as total hydrocarbons in pounds per 24 hour period, pounds of hydrocarbons emitted from the vapor control unit per 1000 gallons of gasoline loaded into vehicles, and processor total hydrocarbon capture efficiency in percent.

Matus Technical Services used EPA test procedures in 40CFR60 Subpart XX, "Standard of Performance for Bulk Gasoline Loading Terminals". The specific parameters measured included the following:

At The Outlet Test Location: Total hydrocarbons by NDIR (Method 25B), exhaust volume by volume meter (Method 2A), volume meter temperature by thermocouple, outlet meter pressure by pressure transducer
At The Inlet Test Location: Total hydrocarbons by NDIR (Method 25B)
Dispensing Operations: Gasoline volume dispensed into vehicles.
Vapor Connections and Vapor Collection Piping: Leak test by explosimeter (Method 21).

Matus Technical Services was responsible for all on-site sampling as well as for the submission of this final report of the test results which include a description of the sampling and analytical methods and the calculations used.

Go to page 2 | 3 | 4 | 5 | 6 | 7 | 8
Download report (Word doc)

Field Testing Summary
Table 1: Explanation of Terms
Table 1 - Field Test Data Summary
PERMEATOR On vs Off Graph
Actual independent third-party test results by Matus Technical Services, Inc.
ARID's Evaporative Loss Model
Average V over L Results
Gasoline RVP Samples
Notes Regarding Field Test Leak Results
Field Test Site Photos - Lantana, Florida
 
Home | Back | Top